Free tool

Cooling Load Calculator

Enter the floor area and the type of space to get an instant estimate of the cooling capacity it needs in tons and kW, and the system that suits it.

Space details

Estimated result

Required cooling load in tons of refrigeration

9.6TR

115,500 BTU/h

kW of cooling
33.9
Airflow (CFM)
3,850
m² per ton
15.6

Suggested system

Concealed ducted units for each zone of the building

An initial estimate that includes a 10% safety margin. It is based on a load density per square metre adjusted for ceiling height, occupancy and sun exposure, and does not replace a detailed load calculation and a site survey.

How is the result calculated?

The calculator starts from an estimated load density per square metre that depends on how the building is used, adjusts it with three factors, then adds a 10% safety margin.

  • Ceiling height: the reference height is 3 m. Each extra metre raises the load by 20%, and each metre less lowers it by the same amount.
  • Occupancy density: a factor of 0.9 for low occupancy, 1 for normal, 1.15 for high and 1.3 for very high.
  • Glazing and sun: a factor of 0.9 for shaded facades, 1 for normal ones, 1.15 for large glazed facades and 1.3 for a fully glazed or exposed west-facing facade.
  • Conversions: one ton of refrigeration equals 12,000 BTU/h or 3.517 kW, and airflow is estimated at about 400 CFM per ton.

Load density used for each building type

Figures before the height, occupancy and glazing factors and before the safety margin.
Building typeBTU/h per m²m² covered by one ton
Villas and majlis70017.1
Residential apartments62019.4
Administrative offices75016.0
Showrooms and shops85014.1
Restaurants and halls1,10010.9
Mosques90013.3
Schools and classrooms80015.0
Gyms and sports clubs95012.6
Insulated warehouses45026.7
Technical and server rooms1,6007.5

When is the calculator not enough?

The calculator gives an initial figure that helps with budgeting and with comparing systems. The final capacity comes from a detailed calculation that accounts for facade orientation, insulation and glass type, number of people, lighting, equipment and the fresh-air quantity.

The calculator is meant for comfort cooling. Cold rooms, freezers and industrial refrigeration are calculated differently, from the product, the storage temperature and how goods move in and out.

Cold Storage & Freezing Rooms

Common questions about cooling load calculation

How many square metres does one ton of air conditioning cover?

It depends on how the building is used. In this calculator one ton covers about 17 m² in villas and 19 m² in apartments before the safety margin. It drops to about 11 m² in restaurants because of the number of people and the kitchen heat, and rises to about 27 m² in insulated warehouses.

What is the difference between a ton of refrigeration and BTU?

One ton of refrigeration equals 12,000 BTU per hour. A unit rated at 18,000 BTU is a 1.5-ton unit, and one rated at 24,000 BTU is a 2-ton unit.

Is the calculator result enough to choose and buy a unit?

It is enough to form a first idea of the capacity and the budget. Before buying or signing a contract you need a detailed calculation and a site survey, especially for commercial projects and buildings with large glazed facades.

Why does the cooling load increase with ceiling height?

The volume of air to be cooled grows and so does the wall area exposed to heat. The calculator adds 20% for each metre above a height of three metres.

Need a final figure for your project?

Send us the drawings or request a site survey. Our team prepares the detailed load calculation and proposes the right system and capacities.

Contact our team